Section 2.2: Changing How the NT9010 Works For Users
31
[17] - [✱]+[1] Reactivate Stay/Away Zones
This function key provides the user with a simple method for adding Stay/Away
zones back into the system (see [*] [1] Zone Bypassing on page 25).
[18] - [26] For Future Use
[27] - Status
Press this key to have the NT9010 announce the time and the current status of the
system. For example, the system may announce:
“Zones are open. Zone 1. Secure system before turning on. For more options,
press [✱].”
Pressing this key while the unit is speaking will cause the unit to stop speaking.
[28] - Volume
To change the volume of NT9010 announcements, press this key. The NT9010 will
announce the different volume levels.
[29] - Record
Press this key to begin recording a message through the NT9010 microphone. After
you hear the prompt “Record Memo Now” and a single 1 second tone, begin
recording your message. When you are finished recording, press [#].
[30] - Playback
Press this key to listen to a recorded message. If there is no message recorded, the
NT9010 will sound an error tone. You can stop playback of the recorded memo any
time by pressing [#].
NOTE:Keys [27] to [30] are instant function keys. They do not have to be
held for 2 seconds to activate.
2.2.11 Programming
Wireless Keys
If you will be adding WLS929-433 wireless keys, after you enroll them on the sys-
tem you may want to change the functions of the buttons on these devices.
If you enable the WLS Key Does Not Use Access Codes option, the disarm but-
ton will work on wireless keys which have not been assigned access codes. To pre-
vent disarming by wireless keys which don’t have access codes, disable this option.
To change wireless key function buttons, from Advanced Programming:
1. Enter section [804].
2. Enter the 2-digit sub-section number of the button you want to program:
[61] = Wireless key button 1
[62] = Wireless key button 2
[63] = Wireless key button 3
[64] = Wireless key button 4