Section 1.2: Installing The NT9010
11
[87] Delayed 24 Hour Fire (Wireless): If this zone is violated (e.g. the
smoke detector senses smoke), the alarm will immediately sound,
but the alarm communication to the central station will be delayed
for 30 seconds. If during the 30 second delay the user presses the [#]
key, the alarm and communicator will be delayed an additional 90
seconds. This provides time for a user to correct the problem.
If after the 90 second delay the zone is still violated the process will
begin again: the alarm will sound but the alarm communication will
be delayed for 30 seconds.
If the user does not press the [#] key, after 30 seconds the alarm will
latch on and the system will communicate a fire alarm to the central
station. The alarm will sound until the Bell Cutoff time expires, or
until a valid code is entered.
Programming Zone Labels
If an enrolled device is a door/window contact, motion detector, glassbreak detec-
tor, or smoke detector the system will then prompt you to enter an audio label for
the new zone. You can choose from any of the following preset audio labels:
If necessary, you can also program custom labels for the zones through the NT9010
Flash Programming.
1. For door/window contacts, motion detectors, and glassbreak detectors, at the
appropriate place in Flash Programming, instead of selecting labels A to E, press
function key F.
2. You can now enter up to six pre-programmed words from the Audio Label
Library. For each word you want to program, enter a 3-digit code from the Label
Library (for a list of labels and codes, see the NT9010 Programming Worksheets,
Appendix A). If your label is less than six words, press [#] at the end of the label.
3. If you want to use a recorded label instead of the words available in the Audio
Label Library, enter [244] for the first label entry, then the number of the label
[001] to [005]. The recorded label will replace all six words in the section. You
will not be able to add additional words to the label. To record a label for a
zone, please see section 2.1.5 Programming Audio Labels on page 16.
4. When you have entered the label, the system will recite it. If the label is correct,
press [1]. If the label is not correct, press [2] and repeat steps 1 to 3 to fix the label.
Press
Function
Key:
Door/window
contacts
(2XXXXX)
Motion or
glassbreak
detector
(3XXXXX)
Smoke detector
(4XXXXX)
A Front door Main floor motion Main floor fire
B Back door Upstairs motion Upstairs fire
C Garage door Downstairs motion Downstairs fire
D Window Hallway motion Hallway fire
E Patio door Garage motion Garage fire