Chapter 1: Quick Set Up
6
To remove the backplate from the NT9010:
1. Remove the plastic screw from the top of the NT9010 unit (see Figure 1). Keep
the screw in a safe location so that you can replace it later.
2. Insert a flathead screwdriver in the slots shown in Figure 1. Twist the screwdriver
so that the backplate separates from the plastic housing.
3. Pull the top of the backplate away from the NT9010.
4. Unhook the backplate from the bottom of the NT9010.
Now you can attach the backplate to the wall:
1. Pull the prepared AC and telephone wires through the square hole in the back-
plate.
2. Place the backplate on the wall in the selected mounting location, and mark the
screw locations.
3. Using wall anchors for all screw locations, secure the backplate to the wall.
1.2.5 Connecting
the Battery
Before you attach the NT9010 to the backplate, you must connect the battery. The
battery is used to provide backup power in the event of an AC power failure and to
provide additional current when necessary, such as when the system is in alarm.
NOTE:Place the unit face down before removing the plastic.
1. Remove the two metal screws at the back of the NT9010.
2. Remove the back plastic from the NT9010.
3. Connect the RED battery lead to the positive (+) terminal of the battery, the
BLACK battery lead to the negative (-) terminal.
4. Replace the back plastic on the NT9010 and secure it with the metal screws.
NOTE:The unit will not power up if only the battery is connected. AC
power must also be connected to the NT9010.
Connecting AC and Telephone Wiring
Connect the AC and telephone line wiring to
the terminals mounted on the NT9010 back-
plate. When you later attach the NT9010 to
the backplate, the posts on the back of the
unit will plug into the terminals, completing
the connection.
AC Terminals
For the NT9010 to work correctly, you will
need to connect it to an AC power source that
is not controlled by a switch. The system
comes with a 9V, 20VA plug-in transformer.
Connect the transformer to an unswitched AC
source and to the two terminals on the back-
plate labelled AC.
NOTE:Risk of fire if the rated voltage is not used. Do not power the Envoy
controller at a voltage higher than 9V AC. Use only transformer Model
PTD920 as supplied with the unit.