2. Let the telephone ring one or two times.
3. Hang up and wait 10 seconds before calling again. The NT9010 will answer
after the first or second ring and announce
“Hello.”
4. Enter the 3-digit Telephone Access Code. If this is not entered within 10 sec-
onds the NT9010 will hang up. Once the correct code has been entered, the
system will prompt,
“Enter your Access Code.”
5. Enter a 4-digit access code. The NT9010 will begin to announce the status of
the system. If you do not enter an access code within 20 seconds, or if you
enter it incorrectly 3 times, the NT9010 will hang up. Invalid access codes
count towards the Keypad Lockout, if enabled (see 2.2.13 Keypad
Options on page 33).
NOTE: The Maintenance Code can be used to access the system from a
remote telephone.
Remote Access Enabled/Disabled . . . . . . . . . . . . . . .Section [807]-[021], Option [1]
2.2.2 Access Codes For instructions on programming access codes, see the NT9010 User’s Guide
(Programming Access Codes).
General access codes can arm and disarm the system. When the Code Required
for Bypassing option is enabled, users will need to enter a valid access code in
order to bypass zones. Individual access codes can have the Zone Bypassing
attribute disabled under Access Code Attribute programming, see Programming
Access Code Attributes on page 20.
The available access codes are as follows:
General Access Codes - Access Codes [01] to [32]
Each access code can be used to arm and disarm the system. Additional access code
attributes are also programmable to determine what abilities the code will have.
You can program access code attributes by following the instructions in this section.
Duress Codes - Access Codes [33] and [34]
When a Duress Code is used to perform any function the system will send a Duress
Reporting Code to the central station (see 2.3.12 Communicator Reporting
Codes on page 44).
Master Code - Access Code [40]
The Master Codes can perform any keypad function. These codes can be used to
program all access codes, including the Duress Codes.
If the Master Code Not Changeable option is enabled users will not be able to
change the Master Code [40]. You will only be able to change it using Advanced
Programming.