Chapter 2: Advanced Programming
22
If the Verbal Chime for Zone Closings is enabled, the NT9010 system will
announce the zone label when the zone is closed. See also [*] [4] Door Chime On/
Off on page 27.
You can create custom labels for the system and for each zone in the Labels pro-
gramming area. Please see 2.1.5 Programming Audio Labels on page 16 for
more information.
Clock is AM/PM. . . . . . . . . . . . . . . . . . . . . . . . . . . .Section [807]-[002], Option [1]
System Status Prompts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Section [807]-[003]
[✱] Command Prompts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Section [807]-[004]
Door Chime Zone Attribute . . . . . . . . . . . . . . . . Sections [101] to [132], Option [3]
Verbal Chime Enabled/Disabled . . . . . . . . . . . . . . . . . . . . Section [017], Option [2]
Verbal Chime for Zone Openings . . . . . . . . . . . . . . . Section [807]-[002], Option [2]
Verbal Chime for Zone Closings. . . . . . . . . . . . . . . .Section [807]-[002], Option [3]
Custom Zone Labels . . . . . . . . . . . . . . . . . . . . .Sections [807]-[601] to [807]-[632]
2.2.4 Alarm
Announce-
ments
If the Verbal Alarm option is turned on, the system will announce the first and last
zones that have gone into alarm, along with the alarm tone. When a zone with the
Audible attribute turned on goes into alarm, the NT9010 system will sound an
alarm tone, but every 15 seconds it will pause the siren and the speaker will
announce the zone(s) in alarm, for example:
“Alarm South Bedroom Window”
You can change the number of seconds between alarm announcements in the
Alarm Tone Period for Verbal Alarm section.
Zones programmed as Silent, and 24 Hour Supervisory Buzzer zones will not be
announced or cause the unit to annunciate at full volume.
NOTE: Fire annunciation always overrides any burglary zone alarm annun-
ciation. Alarms from Fire or Panic keys override all other alarm announce-
ments.
NOTE:The alarm announcements will stop with the siren at the end of the
Bell Time Out period.
Verbal Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Section [017], Option [3]
Alarm Tone Period for Verbal Alarm . . . . . . . . . . . . . . . . . . . . . .Section [807]-[030]
2.2.5 Arming and
Disarming
Options
If the Arm/Disarm Bell Squawk option is enabled the system will squawk the
alarm output once upon arming and twice upon disarming. If an alarm is in mem-
ory, when the system is disarmed the bell will sound three pairs of disarm squawks.
NOTE: If you enable the Bell Squawk on Arming/Disarming (section [014],
option [1]), the bell will sound arm/disarm bell squawks for all access codes,
regardless of the programming for attribute [7] (see 2.2.2 Access Codes on
page 19).