Chapter 2: Advanced Programming
20
Supervisor Codes - Access Codes [41] to [42]
Supervisor Codes can program additional access codes. By default, Supervisor codes
have the same attribute programming as the Master code. You can change the
attribute programming for these codes by following the instructions in this section.
Maintenance Code
The maintenance code can only be used to arm and disarm the system. The main-
tenance code will also allow remote (telephone) access to the system.
It cannot be used to bypass zones, or for any other function. This code can only be
programmed in Advanced Programming.
Installer’s Code
You will use the Installer’s Code to set up and to program the system. The Installer
Code is [5555] at default, but should be changed to prevent unauthorized access
to programming.
Telephone Access Code
If the NT9010 system is connected to the premise telephone line, users will be able
to access their system using a premise or phone (see 2.2.1 Accessing the NT9010
System Using a Telephone on page 18). Users will need to enter a Telephone
Access Code before they can use the NT9010 system. The default Telephone Access
Code is [✱✱✱]. You can change this to any 3 digit code using numbers 0 through 9
as well as the [] and [#] keys. This access code can only be changed through
Advanced Programming.
NOTE: Avoid programming this code as a valid 3 digit area code or tele-
phone service. Avoid numbers such as [911], [411], [611] or [0XX]. Do not try
to exit this section by pressing [#], it will be accepted as a valid digit. To exit,
program all 3 digits of the code or press [Forward].
Programming Access Code Attributes
Attributes determine what abilities an access code will have.
By default, each code has the attributes of the code used to program it. For exam-
ple, if you use the Master code to program other access codes, the new codes will
have the same attributes as the Master code. You can change the attribute pro-
gramming by following the instructions below.
You cannot change Master code attribute programming. The Master code has all
attributes turned on, except for the Bell Squawk on Arming/Disarming attribute.
To program each attribute:
1. Enter [][5][Master code][9] to enter the attribute programming mode.
2. Enter the 2-digit number of the access code you want to edit.
3. Enter the attribute number to toggle it on or off.
The programmable attributes are as follows:
Attribute 1: User enabled for arming, disarming, alarm reset, auto-arm cancel
(on by default)
Attribute 2: For future use
Attribute 3: Zone Bypass enabled
This attribute allows the user to bypass zones.